DNA Marker
15000bp DNA Marker, 250-15000bp
Product description This product contains a DNA molecular weight marker consisting of 7 linear double-stranded DNA fragments at the following sizes: 15,000 bp; 10,000 bp; 7,500 bp; 5,000 bp; 2,500 bp; 1,000 bp; 250 bp. The reference band is 2500 bp, with a concentration of 100 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132121S N132121M Size 100 T 10×100 T Components Component No. Component Name N132121S N132121M N132121-A 15 kb DNA Marker 500 μL 10×500 μL N132121-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 0.6% agarose gels with a voltage of 4–10 V/cm in 0.5×TBE buffer or 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$55.00 - $380.00
12000bp DNA Marker, 100-12000bp
Product description This product contains a DNA molecular weight marker consisting of 20 linear double-stranded DNA fragments at the following sizes: 12,000 bp; 8,000 bp; 6,000 bp; 5,000 bp; 4,000 bp; 3,000 bp; 2,500 bp; 2,000 bp; 1,500 bp; 1,200 bp; 1,000 bp; 900 bp; 800 bp; 700 bp; 600 bp; 500 bp; 400 bp; 300bp; 200 bp; 100 bp. The reference bands are 500 bp, 1,000 bp and 1,500 bp, with a concentration of 60 ng/5 μL, while all other bands are at 20 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132120S N132120M Size 100 T 10×100 T Components Component No. Component Name N132120S N132120M N132120-A 12 kb DNA Marker 500 μL 10×500 μL N132120-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 0.7-1.2% agarose gels with a voltage of 4–10 V/cm in 0.5×TBE buffer or 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$55.00 - $3,000.00
10000bp DNA Marker, 100-10000bp
Product description This product contains a DNA molecular weight marker consisting of 10 linear double-stranded DNA fragments at the following sizes: 100 bp; 250 bp; 500 bp; 750 bp; 1,000 bp; 1,500 bp; 2,000 bp; 4,000 bp; 6,000 bp; 10,000 bp. The reference band is 1,500 bp, with a concentration of 100 ng/5 μL, while all other bands are at 40 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132119S N132119M Size 100 T 10×100 T Components Component No. Component Name N132119S N132119M N132119-A 5 kb DNA Marker 500 μL 10×500 μL N132119-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 1.0-2.0% agarose gels with a voltage of 4–10 V/cm in 0.5×TBE buffer or 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$55.00 - $385.00
5000bp DNA Marker, 100-5000bp
Product description This product contains a DNA molecular weight marker consisting of 9 linear double-stranded DNA fragments at the following sizes: 5,000 bp; 3,000 bp; 2,000 bp; 1,500 bp; 1,000 bp; 750 bp; 500 bp; 250 bp; 100 bp. The reference bands are 1,500 bp and 750 bp, with a concentration of 125 ng/5 μL, while all other bands are at 50 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132118S N132118M Size 100 T 10×100 T Components Component No. Component Name N132118S N132118M N132118-A 5 kb DNA Marker 500 μL 10×500 μL N132118-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 1.0-2.0% agarose gels with a voltage of 4–10 V/cm in 0.5×TBE buffer or 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$45.00 - $305.00
2000bp DNA Marker, 100-2000bp
Product description This product contains a DNA molecular weight marker consisting of 6 linear double-stranded DNA fragments at the following sizes: 2,000 bp; 1,000 bp; 750 bp; 500 bp; 250 bp; 100 bp. The reference band is 750 bp, with a concentration of 125 ng/5 μL, while all other bands are at 50 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132117S N132117M Size 100 T 10×100 T Components Component No. Component Name N132117S N132117M N132117-A 2 kb DNA Marker 500 μL 10×500 μL N132117-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 1.0-2.0% agarose gels with a voltage of 4–10 V/cm in 0.5×TBE buffer or 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$55.00 - $385.00
500bp DNA Ladder, 500-5000bp
Product description This product contains a DNA molecular weight marker consisting of 8 linear double-stranded DNA fragments at the following sizes: 500 bp; 1,000 bp; 1,500 bp; 2,000 bp; 2,500 bp; 3,000 bp; 4,000 bp; 5,000 bp. The reference band is 2,500 bp, with a concentration of 100 ng/5 μL, while all other bands are at 40 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132115S N132115M Size 100 T 10×100 T Components Component No. Component Name N132115S N132115M N132115-A 500 bp DNA Ladder 500 μL 10×500 μL N132115-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 1.5-2.0% agarose gels with a voltage of 4–10 V/cm in 0.5×TBE buffer or 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$55.00 - $385.00
200bp DNA Ladder, 200-5000bp
Product description This product contains a DNA molecular weight marker consisting of 12 linear double-stranded DNA fragments at the following sizes: 200 bp; 400 bp; 600 bp; 800 bp; 1,000 bp; 1,200 bp; 1,400 bp; 1,600 bp; 1,800 bp; 2,000 bp; 3,000 bp; 5,000 bp. The reference band is 1,200 bp, with a concentration of 100 ng/5 μL, while all other bands are at 40 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132114S N132114M Size 100 T 10×100 T Components Component No. Component Name N132114S N132114M N132114-A 200 bp DNA Ladder 500 μL 10×500 μL N132114-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 1.5-2.0% agarose gels with a voltage of 4–10 V/cm in 0.5×TBE buffer or 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$55.00 - $385.00
100bp plus DNA Ladder, 100-3000bp
Product description This product contains a DNA molecular weight marker consisting of 14 linear double-stranded DNA fragments at the following sizes: 100 bp; 200 bp; 300 bp; 400 bp; 500 bp; 600 bp; 700 bp; 800 bp; 900 bp; 1,000 bp; 1,200 bp; 1,500 bp; 2,000 bp; 3,000 bp. The reference bands are 500 bp and 1,200 bp, with a concentration of 120 ng/5 μL, while all other bands are at 50 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132113S N132113M Size 100 T 10×100 T Components Component No. Component Name N132113S N132113M N132113-A 100 bp Plus DNA Ladder 500 μL 10×500 μL N132113-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 1.5-2.0% agarose gels with a voltage of 4–10 V/cm in 0.5×TBE buffer or 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$55.00 - $380.00
100bp DNA Ladder, 100-1500bp
Product description This product contains a DNA molecular weight marker consisting of 12 linear double-stranded DNA fragments at the following sizes: 1500 bp; 1200 bp; 1000 bp; 900 bp; 800 bp; 700 bp; 600 bp; 500 bp; 400 bp; 300 bp; 200 bp; 100 bp. The reference band is 500 bp, with a concentration of 125 ng/5 μL, while all other bands are at 50 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132112S N132112M Size 100 T 10×100 T Components Component No. Component Name N132112S N132112M N132112-A 100 bp DNA Ladder 500 μL 10×500 μL N132112-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 1.0-2.0% agarose gels with a voltage of 4–10 V/cm in 0.5×TBE buffer or 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$55.00 - $380.00
50bp DNA Ladder, 50-1000bp
Product description This product contains a DNA molecular weight marker consisting of 14 linear double-stranded DNA fragments at the following sizes: 50 bp; 100 bp; 150 bp; 200 bp; 250 bp; 300 bp; 350 bp; 400 bp; 500 bp; 600 bp; 700 bp; 800 bp; 900 bp; 1,000 bp. The reference bands are 250 bp and 500 bp, with a concentration of 100 ng/5 μL, while all other bands are at 40 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132111S N132111M Size 100 T 10×100 T Components Component No. Component Name N132111S N132111M N132111-A 50 bp DNA Ladder 500 μL 10×500 μL N132111-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 1.5-2.0% agarose gels with a voltage of 4–10 V/cm in 0.5×TBE buffer or 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$55.00 - $385.00
1000bp DNA Ladder, 250-12000bp
Product description This product contains a DNA molecular weight marker consisting of 13 linear double-stranded DNA fragments at the following sizes: 12,000 bp; 8,000 bp; 6,000 bp; 5,000 bp; 4,000 bp; 3,000 bp; 2,500 bp; 2,000 bp; 1,500 bp; 1,000 bp; 750 bp; 500 bp; and 250 bp. The reference bands are 4,000 bp and 1,500 bp, with a concentration of 100 ng/5 μL, while all other bands are at 40 ng/5 μL. The marker is supplied in 1×DNA Loading Buffer and is designed for agarose gel electrophoresis analysis of DNA bands. It is not recommended for polyacrylamide gel electrophoresis (PAGE). Specifications Product No. N132116S N132116M Size 100 T 10×100 T Components Component No. Component Name N132116S N132116M N132116-A 1 kb DNA Ladder 500 μL 10×500 μL N132116-B 5×DNA Loading Buffer 1 mL 10×1 mL Shipping and Storage Store at room temperatures or at 2°C to 8°C, valid for half a year. Stor at -25℃ to -15℃, valid for one year. Avoid repeated freeze-thaw cycles. Notes 1. For optimal electrophoresis results: 1) Ensure thorough mixing of the product before use. 2) Replace the electrophoresis buffer promptly and use freshly prepared gels. 2. If smearing, blurred bands, or distortion occurs during electrophoresis: Dilute the sample with water before loading. For standard-width gel wells, dilute the sample 5-fold with water and load 8-10 μL. 3. When switching to a new stain or using agarose gels containing different stains: 1) Thoroughly clean the electrophoresis tank to avoid cross-contamination. 2) Replace with fresh electrophoresis buffer after cleaning. 4. For your safety and health, please wear a lab coat and disposable gloves. 5. For research use only! Instructions 1. Load 5 μL of the DNA ladder. For wide wells, increase the loading volume appropriately. 2. Use 0.7–1.2% agarose gels with a voltage of 4–10 V/cm in 1×TAE buffer. 3. Visualize DNA bands under UV light if stain the gel using solution-based staining methods with ethidium bromide (EB) or Arcegen Nucleic Acid Stain (Cat# N132109, non-toxic and UV-compatible).
$50.00 - $345.00