NGS rRNA Depletion Kit (Plant) _ N210401

Description

.Product description

NGS rRNA Depletion Kit (Plant) utilizes RNase H digestion to remove ribosomal RNA (including cytoplasmic 18S, 25S rRNA, mitochondrial 18S, 26S rRNA, and chloroplast 16S, 23S rRNA) from total RNA of plant origin, thereby preserving messenger RNA (mRNA) and other non-coding RNA. This kit provides effective rRNA removal for both intact and partially degraded total RNA samples. The RNA samples obtained after rRNA depletion can be used for high-throughput sequencing to analyze mRNA and non-coding RNA, significantly increasing the proportion of usable sequencing data. They can also be used for cDNA synthesis or other downstream applications.

Application

Suitable for total RNA samples from various plant sources ranging from 100 ng to 1 μg; suitable for both intact and partially degraded RNA samples.

Specifications

Cat.No.

N210401E / N210401S / N210401M

Size

12 T / 24 T / 96 T

Components

Components No.

Name

N210401E

N210401S

N210401M

N210401-A

Hybridization Buffer

36 μL

72 μL

288 μL

N210401-B

Probe Mix (Plant)

36 μL

72μL

288 μL

N210401-C

RNase H Buffer

36 μL

72 μL

288 μL

N210401-D

Thermostable RNase H

24 μL

48 μL

192 μL

N210401-E

DNase I Buffer

330 μL

660 μL

2×1320 μL

N210401-F

DNase I

30 μL

60 μL

240 μL

Storage

Shipped on dry ice, store at -25~-15 °C.Valid for one year.

Notes

1. Please use RNase-free consumables and regularly clean the work area. Thermo Fisher Scientific’s RNAZap™ High-Efficiency Nuclease Removal Spray is recommended for RNase contamination removal.

2. RNA samples should be free of genomic DNA contamination. If gDNA is present, perform DNase I digestion followed by purification before using this kit.

3. The maximum input volume for RNA samples is 10 μL. If the sample volume exceeds this, concentrate the RNA before use.

4. If the RNase H digestion step requires a reaction mix, please prepare it freshly before use.

5. For personal safety and health, wear a lab coat and disposable gloves during operation.

6. This product is for research use only.

Documents:

NGS rRNA Depletion Kit (Plant) _ N210401

Product form

SKU: N210401S

$1,815.00

    • In stock

      Description

      .Product description

      NGS rRNA Depletion Kit (Plant) utilizes RNase H digestion to remove ribosomal RNA (including cytoplasmic 18S, 25S rRNA, mitochondrial 18S, 26S rRNA, and chloroplast 16S, 23S rRNA) from total RNA of plant origin, thereby preserving messenger RNA (mRNA) and other non-coding RNA. This kit provides effective rRNA removal for both intact and partially degraded total RNA samples. The RNA samples obtained after rRNA depletion can be used for high-throughput sequencing to analyze mRNA and non-coding RNA, significantly increasing the proportion of usable sequencing data. They can also be used for cDNA synthesis or other downstream applications.

      Application

      Suitable for total RNA samples from various plant sources ranging from 100 ng to 1 μg; suitable for both intact and partially degraded RNA samples.

      Specifications

      Cat.No.

      N210401E / N210401S / N210401M

      Size

      12 T / 24 T / 96 T

      Components

      Components No.

      Name

      N210401E

      N210401S

      N210401M

      N210401-A

      Hybridization Buffer

      36 μL

      72 μL

      288 μL

      N210401-B

      Probe Mix (Plant)

      36 μL

      72μL

      288 μL

      N210401-C

      RNase H Buffer

      36 μL

      72 μL

      288 μL

      N210401-D

      Thermostable RNase H

      24 μL

      48 μL

      192 μL

      N210401-E

      DNase I Buffer

      330 μL

      660 μL

      2×1320 μL

      N210401-F

      DNase I

      30 μL

      60 μL

      240 μL

      Storage

      Shipped on dry ice, store at -25~-15 °C.Valid for one year.

      Notes

      1. Please use RNase-free consumables and regularly clean the work area. Thermo Fisher Scientific’s RNAZap™ High-Efficiency Nuclease Removal Spray is recommended for RNase contamination removal.

      2. RNA samples should be free of genomic DNA contamination. If gDNA is present, perform DNase I digestion followed by purification before using this kit.

      3. The maximum input volume for RNA samples is 10 μL. If the sample volume exceeds this, concentrate the RNA before use.

      4. If the RNase H digestion step requires a reaction mix, please prepare it freshly before use.

      5. For personal safety and health, wear a lab coat and disposable gloves during operation.

      6. This product is for research use only.