50× ROX Reference Dye

Description

Product description

The ROX Reference Dye is used on real-time PCR amplification instruments from companies such as ABI and Stratagene to correct inter-well errors caused by pipetting. The concentration of this product is 25 µM.

Components

Components No.

N132049E

N132049S

N132049M

Size

100 μL

500 μL

1 mL

Shipping and Storage

Dry ice shipping. Packaging and storage in the dark to avoid repeated freezing and thawing.-15℃ ~ -25℃ storage, valid for two years.For short-term use, it can be kept at 4°C.

Notes

1. For your safety and health, please wear lab coats and disposable gloves for operation.

2. This product is for research use ONLY!

Instructions

1. 50× ROX Reference Dye

For the quantitative system preparation: Add 1 µL of 50× ROX Reference Dye to a 50 µL qPCR system.

2. 50× ROX Reference Dye II

1) Preparation method for 50× ROX Reference Dye II: Dilute the 50× ROX Reference Dye by 10 times*.

ROX Dilution Solution: 20 mM Tris-HCl (pH 8.4), 0.1 mM EDTA, 0.01% Tween 20.

2) For the quantitative system preparation: Add 1 µL of 50× ROX Reference Dye II to a 50 µL qPCR system**.

Note】: *It can be diluted and added proportionally according to the size of the system; **For multi-well systems, it is recommended to prepare a pre-mixed solution, and use it after thorough mixing.

Applicable Models

1. 50× ROX Reference Dye applicable models

ABI 5700, 7000, 7300, 7700, 7900HT Fast, StepOne, StepOne Plus.

2. 50× ROX Reference Dye II applicable models

ABI 7500, 7500 Fast, ViiA7, QuantStudio 3 and 5, QuantStudio 6, 7, 12k Flex.

Stratagene MX3000P, MX3005P, MX4000P

3. Instrument models that do not require Rox correction

Bio-Rad CFX96, CFX384, iCycler iQ, iQ 5, MyiQ, MiniOpticon, Opticon, Opticon 2, Chromo4.

Roche Applied Science LightCycler 480, LightCycler 2.0; LightCycler 96.

Eppendorf Mastercycler ep realplex, realplex 2 s.

Qiagen Corbett Rotor-Gene Q, Rotor-Gene 3000, Rotor-Gene 6000.

Thermo Scientific PikoReal Cycler.

Cepheid SmartCycler.

Illumina Eco qPCR.

50× ROX Reference Dye

Product form

SKU: N132049E

$20.00

    • In stock
    • Shipped today? Order within: Jul 11, 2025 17:00:00 -0400

    Description

    Product description

    The ROX Reference Dye is used on real-time PCR amplification instruments from companies such as ABI and Stratagene to correct inter-well errors caused by pipetting. The concentration of this product is 25 µM.

    Components

    Components No.

    N132049E

    N132049S

    N132049M

    Size

    100 μL

    500 μL

    1 mL

    Shipping and Storage

    Dry ice shipping. Packaging and storage in the dark to avoid repeated freezing and thawing.-15℃ ~ -25℃ storage, valid for two years.For short-term use, it can be kept at 4°C.

    Notes

    1. For your safety and health, please wear lab coats and disposable gloves for operation.

    2. This product is for research use ONLY!

    Instructions

    1. 50× ROX Reference Dye

    For the quantitative system preparation: Add 1 µL of 50× ROX Reference Dye to a 50 µL qPCR system.

    2. 50× ROX Reference Dye II

    1) Preparation method for 50× ROX Reference Dye II: Dilute the 50× ROX Reference Dye by 10 times*.

    ROX Dilution Solution: 20 mM Tris-HCl (pH 8.4), 0.1 mM EDTA, 0.01% Tween 20.

    2) For the quantitative system preparation: Add 1 µL of 50× ROX Reference Dye II to a 50 µL qPCR system**.

    Note】: *It can be diluted and added proportionally according to the size of the system; **For multi-well systems, it is recommended to prepare a pre-mixed solution, and use it after thorough mixing.

    Applicable Models

    1. 50× ROX Reference Dye applicable models

    ABI 5700, 7000, 7300, 7700, 7900HT Fast, StepOne, StepOne Plus.

    2. 50× ROX Reference Dye II applicable models

    ABI 7500, 7500 Fast, ViiA7, QuantStudio 3 and 5, QuantStudio 6, 7, 12k Flex.

    Stratagene MX3000P, MX3005P, MX4000P

    3. Instrument models that do not require Rox correction

    Bio-Rad CFX96, CFX384, iCycler iQ, iQ 5, MyiQ, MiniOpticon, Opticon, Opticon 2, Chromo4.

    Roche Applied Science LightCycler 480, LightCycler 2.0; LightCycler 96.

    Eppendorf Mastercycler ep realplex, realplex 2 s.

    Qiagen Corbett Rotor-Gene Q, Rotor-Gene 3000, Rotor-Gene 6000.

    Thermo Scientific PikoReal Cycler.

    Cepheid SmartCycler.

    Illumina Eco qPCR.

    © 2025 Arcegen, Powered by Shopify

    • American Express
    • Apple Pay
    • Diners Club
    • Discover
    • Google Pay
    • Mastercard
    • Shop Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account